... both possibilities for doubling that mentioned the monitor volumes should have listed both "USB Volume" and "Monitor Volume" trims. They are in...
If you hear doubling then you have a routing issue. If turning the USB monitor down to 0 fixes the issue then it'd be better to prevent the audio (o...
Scenes with cutoff/resonance offsets will offset when a Performance is recalled if the default scene button that is selected (when [STORE]ing the Perf...
As an update ... what I said earlier about scenes isn't true. I had been operating previously with the false sense that scenes were a way to override...
It would have been more inconsistent for any given feature to NOT have a screwy exception that's counter intuitive. I'm hoping this tradition can b...
Use a scene to store the superknob position set at the golden value then [STORE] your Performance with that scene activated. This is a no AI zone ....
In the other thread one workflow suggestion I made (one way that works) was to disable keyboard control on all Parts. Then in order for the controls ...
Keyboard Control turns off the piano key presses and knob twirling for each Part that has Keyboard Control turned off (and not selected). If you ...
The piano keyboard won't send keypresses to the piano. The pattern sequencer won't record these for the piano channel so playback will only have the ...
Turn off keyboard control for the piano Part while recording your drum sequence. The piano won't play and that MIDI channel (track) shouldn't record ...
Blake touches the "1-4/5-8" buttons located to the left of the sliders and to the left of the scene buttons. Then he shows that the knobs are showing ...
Dry/Wet is assignable for insertion effects. There's an opportunity to reconfigure a system effect to an insertion then use Dry/Wet as a means to get...
I have expertise in electrical design including power supply design. I'm not recommending using the "wrong" power supply but wanted to counter that t...
Just so you know - the power supply for the S-30 is powering 5V and 9V regulators. These regulator specs will determine the voltage ranges accepted. ...
Normally [ASSIGN] switches the knobs between 1-4 and 5-8 where the button will flash (or not) depending on the bank selected. Using the remote featu...