Here is the solution (tested): Send to Montage F0 43 10 7F 1C 02 09 00 00 XX F7 (parameter change with adress = 09 00 00) Send to Modx F0 43...
@Shawn: You can't just send part name to change a part. Your message is a parameter change to modify part 5 data (name and other parameters). Ple...
Hi Jean, What is not documented in datalist from the first version is how to dump all the Live Sets. You can only dump the current live Set. (...
You can create scene 2 from measure 1 to 8, and scene 3 from measure 9 to 16, while muting what you want in each scene. You have tools to copy and sp...
Hi, Jean I agree with you: The data list is not complete. For example, in livesets, there is no information on perform/song/audio/pattern choice, ...
You go to Utility > Contents > Library Import, and you select the library. You count number of pages times 12 . @+
Hi, Done your test with MidiOx. This message is for requesting a dump of current performance edit buffer (data list 2.00_g0 p190). So I receive ...
Hi, You have to make a 'backup' file before upgrading OS. Then, after upgrade, load your backup file. If you only load a 'user' file, the midi ...
Hi You have to send 'Bank select MSB' + 'Bank select LSB' + 'Program change' messages. Note: all the commands are written in hexadecimal. To lo...
Hi, You cannot change midi channel of a part, so you have to put the drum part on the channel of the midi file. Look at reaper to see what channe...
Hi To Stefan: The Montage sends sysex for scene changes and superKnob, if it does not have a controller message assigned in Utility> Settings> M...
Hi I tried (with my PC) to send an exclusive message to change the part parameter called 'keyboard control switch' = 'off' or 'on'. F0 43 10 7F 1C...
If you can't touch "Calibrate Touch Panel" on the screen, you can run it directly with buttons [UTILITY] and [PART COMMON]. ( [PART COMMON] is just o...
Good job Jean. It works fine on Win10 64b