Eminent Member
Joined: May 3, 2016
Topics: 13 / Replies: 83
Reply
MODX Sysex Further Applications

Reloading some old perfs from Montage and Modx my soft have saved on disk with my own format( I save all blocs I receive on disk). It seems that bloc...

4 years ago
Reply
MODX Sysex Further Applications

Exactly the same thing and observations on Modx.

4 years ago
Reply
HOW TO: Send SysEx Commands to MODX

For the liveset new parameters: Page 196 of datalist : bloc 04 ps 00 and bloc 05 ps 00 have now a TOTAL SIZE of 32(d) not 26(d) At offset 1A ...

4 years ago
Reply
HOW TO: Send SysEx Commands to MODX

@Tino: Hello. Yes I receive 00.7F.00 , I search what it is For now, no idea.

4 years ago
Reply
HOW TO: Send SysEx Commands to MODX

Errata: n varies from 0 to 8 not 0 to 7. Here is the protocol to write liveset: First select your liveset by sending parameter change 09.00.00...

4 years ago
Reply
HOW TO: Send SysEx Commands to MODX

I agree there are some errors in the datalist. It is true this is an error page 187. Page 194 'Midi Mode' at 00.00.30 have never been documented...

4 years ago
Reply
HOW TO: Send SysEx Commands to MODX

@ Jason: I have not said if blocs are not in the order you see in datalist then this is a transmission error. I would say if you don't find blo...

4 years ago
Reply
HOW TO: Send SysEx Commands to MODX

@ Jason: I think you have assume of the order of the blocks but the datalist said : "The Block from the Bulk Header to the Bulk Footer of the Perform...

5 years ago
Reply
HOW TO: Send SysEx Commands to MODX

@HSL: If you are programmer, I suggest you make a quick program, that request a performance, store it to memory. Then after changing a parameter on ...

5 years ago
Reply
HOW TO: Send SysEx Commands to MODX

Hi HSL 1) 0E.25.00 is for requesting the entire performance (common + all active parts) 0E.52.nn is for requesting the part nn (0..15), if the pa...

5 years ago
Reply
HOW TO: Send SysEx Commands to MODX

If you request a bulk dump with 0E.25.00 you will receive the entire buffered performance. That is the performance common and all active performance...

5 years ago
Reply
Datalist for OS 3.0 not up to date

They will likely make the next publication of the Data List. Ok. Thank you.

5 years ago
Reply
Library Slot?

@ BM : I will try to deepen what you say about assignable knobs (and I make a mistake in single mode common assignable knobs send CC no sysex). ...

6 years ago
Reply
Library Slot?

Ok I am trying to explain what I want doing. But, please, keep in mind I have a bad english, I use transaltor, dico, and I don't always know if ...

6 years ago
Reply
Library Slot?

Just want to say, when playing in single channel mode, moving faders in common mode generate no midi messages, moving knobs in part mode (a part is se...

6 years ago