Reply
DUMP REQUEST - HOW TO USE?

The docs give instructions. If you want to dump the current Performance you have recalled, use: F0, 43, 20, 7F, 1C, 07, 0E, 25, 00, F7 This s...

3 years ago
Reply
Performance understanding

When I stay on Part1 and change velocity shift I hear changes really. When I open Common settings velocity shift changes has not any result. I not he...

3 years ago
Reply
DUMP REQUEST - HOW TO USE?

This is I am recording Master EQ 🙂 But 18 entry writing manulally it's hardlly. One good that it's possible to save as midi file as template

3 years ago
Topic
Replies: 14
Views: 1122
Reply
DUMP REQUEST - HOW TO USE?

It does seem to be all other use PARAMETER REQUEST... Selectively is not good. More requests, more records... Although perhaps for Performance it is...

3 years ago
Topic
Replies: 8
Views: 998
Reply
Instrument Definition for Montage

125, 063, 016 "Ambient Synth Pad 2" 116, 063, 016 "Updraft" 118, 063, 016 "Ozone Cleaner" 008, 063, 017 "Super Slicer" somelike xxx,xxx,020 is 1...

3 years ago
Reply
Project from scratch

DRUM VOICE KEY | Address | Size | Data Range (HEX) } Parameter Name | Description | | 5p kk 06 | 2 | 00 – 1F ; 00 – 7F | Wave Number | 1 – 6347 (U...

3 years ago
Reply
Project from scratch

I am trying to find the correct algorithm of actions. I need to enable sidechain from Cubase/Nuendo via SysEx or CC. Is it A/B FX buttons are pressed...

3 years ago
Reply
Project from scratch

Address 31 2p 17 Insertion-A Parameter 11 (?) I'm searching Side Chain Level... What is MSB/LSB mean here? No documentation enough. +24dB -Infini...

3 years ago
Reply
Project from scratch

How to press button solo via SysEx ? 00 F0 SysEx 01 43 Yamaha ID 02 10 Device Number 03 7F Group ID High 04 1C Group ID Low 05 07 Model ID 06...

3 years ago
Reply
Cool FM Bass

Now I understand how to start it. Modulator or Carrier and any Operators: first It need to modify volume and coarse (optional) Volume get to listen ...

3 years ago
Reply
Project from scratch

Maybe I should do it differently? First, create a performance for the project and work with it? OK... // I tried MODX Connect - useless stuff. Load...

3 years ago
Reply
Project from scratch

Change SysEx H/M/L addresss 00/00/00 (one byte) to change the tone generator volume. 00/00/00 What the SysEx? F7 43 10 7F 1C 07 31 00 24 80 F7 ~ MID...

3 years ago
Reply
Cool FM Bass

Das ist fantastisch!!! 🙂 Cool Bass! When I looked at the algorithms myself, I did not understand why some schemes are silent I couldn't do it m...